Please note that right ventricular infarction and posterolateral infarction will be discussed in detail later on. The conventional placement of electrodes can be suboptimal in some situations.
Electrodes placed distally on the limbs will record too much muscle disturbance during exercise stress testing; electrodes on the chest wall may be inappropriate in case of resuscitation and echocardiographic examination etc. Efforts have been made to find alternative electrode placements, as well as reducing the number of electrodes without loosing information.
In general, lead systems with less than 10 electrodes can still be used to compute the all standard leads in the lead ECG. Such calculated ECG waveforms are very similar to the original lead ECG waveforms, with some minor differences that may affect amplitudes and intervals. As a rule of thumb, modified lead systems are fully capable of diagnosing arrhythmias but one should be cautious when using these systems to diagnose morphological conditions e.
Indeed, in the setting of myocardial ischemia one millimeter may make a life-threatening difference. Lead systems with reduced electrodes are still used daily to detect episodes of ischemia in hospitalized patients. This is explained by the fact that when monitoring continuously — i. Instead the interest lies in the dynamics of the ECG and in that scenario the initial recording is of little interest.
This is used in all types of ECG monitoring arrhythmias, ischemia etc. It is also used for exercise stress testing as it avoids muscle disturbances from the limbs.
As stated above, the initial recording may differ slightly in amplitudes so that it is not valid to diagnose ischemia on the initial tracing. For monitoring ischemia over time, however, Mason-Likar is an effective system. Refer to Figure 24 A. The left and right arm electrodes are moved to the trunk, 2 cm beneath the clavicle, in the infraclavicular fossa Figure 24 A.
The left leg electrode is placed in the anterior axillary line between the iliac crest and the last rib. The right leg electrode can be placed above the iliac crest on the right side. Placement of the chest leads is not changed. As mentioned above, it is possible to construct mathematically a lead system with fewer than 10 electrodes.
In general, mathematically derived lead systems generate ECG waveforms that are almost identical to the conventional lead ECG, but only almost. It is generated by means of 7 electrodes Figure 22 B. Using these leads, 3 orthogonal leads X, Y and Z are derived. These leads are used in vectorcardiography VCG. Orthogonal means that the leads are perpendicular to each other. These leads offer a three-dimensional view of the cardiac vector during the cardiac cycle.
However, the VCG has lost much ground in recent decades as it has become evident that the VCG has very low specificity for most conditions. VCG will not be discussed further here. Lead X is derived from A, C and I. Lead Y is derived from F, M and H. EASI also provides orthogonal information.
The Cabrera format of the lead ECG. Cardiac electrophysiology: action potentials, automaticity, electrical vectors. Video lecture on ECG interpretation. No products in the cart. Sign in Sign up. Search for:. Introduction to ECG Interpretation. Clinical electrocardiography and ECG interpretation. Arrhythmias and arrhythmology. Mechanisms of cardiac arrhythmias: from automaticity to re-entry reentry.
Conduction Defects. Overview of atrioventricular AV blocks. Atrial and ventricular enlargement: hypertrophy and dilatation on ECG. Exercise stress test treadmill test, exercise ECG : Introduction. Section 1, Chapter 3. In Progress. Electrophysiological basis of the ECG leads. The lead ECG. The ECG paper.
Derivation of the ECG leads. Anatomical planes and ECG leads. Principles of the limb leads. The PR interval begins at the star t of the P wave and ends at the beginning of the Q wave. It represents the time taken for electrical activity to move between the atria and the ventricles.
The ST segment starts at the end of the S wave and ends at the beginning of the T wave. The ST segment is an isoelectric line that represents the time between depolarisation and repolarisation of the ventricles i.
The RR interval begins at the peak of one R wave and ends at the peak of the next R wave. It represents the time taken for the ventricles to depolarise and then repolarise. The paper used to record ECGs is standardised across most hospitals and has the following characteristics:. An ECG electrode is a conductive pad that is attached to the skin to record electrical activity.
Only 10 physical electrodes are attached to the patient, to generate the 12 leads. The data gathered from these electrodes allows the 12 leads of the ECG to be calculated e. The electrodes used to generate a 12 lead ECG are described below.
This is because each lead is recording the electrical activity of the heart from a different direction a. When the electrical activity within the heart travels towards a lead you get a positive deflection.
When the electrical activity within the heart travels away from a lead you get a negative deflection. In reality, electrical activity in the heart flows in many directions simultaneously. Each deflection a. The height of the deflection represents the amount of electrical activity flowing in that direction i.
If the R wave is greater than the S wave it suggests depolarisation is moving towards that lead. This wave possibly results from "afterdepolarizations" of the ventricles. A concise history of the ECG is presented in a different chapter. Electrical activity going through the heart can be measured by external skin electrodes.
The electrocardiogram ECG registers these activities from electrodes which have been attached onto different places on the body. In total, twelve leads are calculated using ten electrodes. It makes no difference whether the electrodes are attached proximal or distal on the extremities. However , it is best to be uniform in this. With the use of these 10 electrodes, 12 leads can be derived. There are 6 extremity leads and 6 precordial leads.
Example : V1 is close to the right ventricle and the right atrium. Signals in these areas of the heart have the largest signal in this lead. V6 is the closest to the lateral wall of the left ventricle. Throughout history extra lead positions have been tried. Most are rarely used in practice, but they can deliver very valuable diagnostic clues in specific cases. A ladder diagram is a diagram to explain arrhythmias. The figure shows a simple ladder diagram for normal sinus rhythm, followed by av-nodal extrasystole.
The origin of impulse formation sinus node for the first two beats and AV junction for the third beat and the conduction in the heart are shown. Also read the chapter about Technical Problems. That will help you recognize electrical disturbances and lead reversals. Hoffa M, Ludwig C.
Einige neue versuche uber herzbewegung. Zeitschrift Rationelle Medizin, 9: Waller AD. Complex: The combination of multiple waves grouped together. Each will be explained individually in this tutorial, as will each segment and interval. The P wave indicates atrial depolarization. The T wave comes after the QRS complex and indicates ventricular repolarization. Back to Healio.